Infrared Thermal Imaging Gallery
Advanced Search
RSS Feed for this Album View Slideshow (Fullscreen)

Random Image

Refractoryfailure2

Refractoryfailure2

Date: 08/20/2008 Views: 43

Infrared Thermal Imaging Gallery

A collection of thermal images by Richardson Building Diagnostics, LLC

Date: 02/12/2008
Owner: Kevin A. Richardson
Size: 18 items
nextlast
IR_0999-horz
 
 

IR_0999-horz

Energy Loss: Leaky ducts inside wall cavity.

Date: 06/08/2008
Owner: Kevin A. Richardson
Views: 116
5 votes
3
IR_0926-tile
 
 

IR_0926-tile

Latent Moisture: The sellers on this inspection disclosed that the basement flooded due to a back-up on an exterior entry door drain. They pulled all of the carpets up and placed two De-humidifiers in the basement. My clients did not know the extent of da

Date: 05/21/2008
Owner: Kevin A. Richardson
Views: 111
5 votes
3.2
IR20080624
 
 

IR20080624

Main disconnect breaker: High temperature rise consistent with high resistant connection or internal breaker failure.

Date: 06/25/2008
Owner: Kevin A. Richardson
Views: 118
5 votes
3
Isotherm_Example
 
 

Isotherm_Example

Energy Loss: Missing insulation on flange (coupling) for a commercial expansion tank.

Date: 08/20/2008
Owner: Kevin A. Richardson
Views: 49
5 votes
3
Refractoryfailure1
 
 

Refractoryfailure1

Mechanical: this is an image of the outer casing of a large boiler/generator, where it is evident that the refractory brick has become deteriorated or compromised.

Date: 08/20/2008
Owner: Kevin A. Richardson
Views: 40
5 votes
3
Refractoryfailure2
 
 

Refractoryfailure2

Mechanical: this is an image of the outer casing of a large boiler/generator, where it is evident that the refractory brick has become deteriorated or compromised.

Date: 08/20/2008
Owner: Kevin A. Richardson
Views: 43
5 votes
3
ScorchMark_Furnace
 
 

ScorchMark_Furnace

This is an image of the back panel of a residential forced air gas furnace. The heat exchanger was cracked, causing this scorch mark on the outer casing.

Date: 08/20/2008
Owner: Kevin A. Richardson
Views: 47
5 votes
3
leakywalls
 
 

leakywalls

Latent Moisture: Here is an image where the condensate drain pipe for the A/C system in the attic was terminated too close to the soffit. The drain was dumping water on the exterior house wall and the interiors walls.

Date: 08/20/2008
Owner: Kevin A. Richardson
Views: 55
5 votes
3
IR_1307
 
 

IR_1307

Mechanical: Circulating pump running hotter than normal.

Date: 08/19/2008
Owner: Kevin A. Richardson
Views: 41
5 votes
3
nextlast